Mini Clean Flow – High Pressure

Mini Clean Flow Heater – High Pressure

BACKGROUND

The BCE application required a custom heating solution at 0.25 CFM with an operating temperature of 800°F (427°C) and an inlet pressure of 800 PSI. The medium being heated was nitrogen. Stainless steel (such as 316) and nickel alloy 600 were used for the heat source in this low flow/mid-temp application.

SPECIFICATIONS

  • Outlet temperature needed to be 800°F (427°C)
  • Inlet needed to withstand 800 PSI
  • Perpendicular configuration with 1/2" tube fittings
  • Hydrostatically pressure tested to 2000 PSI for 1 minute
  • Must pass all electrical tests before and after the 2000 PSI test
  • Ability to place the heater in a vertical flow position if necessary
  • Type "K" thermocouple for additional temperature measurement
  • 300-Watt, 120 Volt
  • Material: 316SS with Nickel 600 Alloy heat source

OUTCOME

High Pressure Gauge

After the 2000 PSI test, the MCF heater was tested to 212°F at 1-3 CFM in the lab. We then re-tested it electrically, checking for any abnormal readings. The tests performed were the meg-ohm insulation resistance at 500 VDC and a hi-pot, 700 VDC test. The heater passed with no changes from the initial inspection prior to the 2000 PSI test.

The heater was cleaned, packaged, and prepared for delivery to the customer.

DRAWINGS

QUALITY

BCE Engineering & Quality Assurance

BCE engineers provide decades of experience in design and development, delivering a wealth of empirical data and experience. BCE welcomes your custom requirement and will design and deliver a part that meets your challenging needs.

BCE is recognized for its commitment to quality and excellence by being certified in accordance with ISO 9001:2015.
ISO 9001

REQUEST MORE INFORMATION HERE

Please fill out the quick form below and we will follow-up immediately.
*Name 
Company 
*Email 
Phone 
*Application details or question 
* Required Field

Case Studies

Signup for our Newsletter





21060 Corsair Blvd. Hayward, CA 94545 | (510) 274-1990
BCE Privacy Policy
© Copyright Belilove Company - Engineers. All Rights Reserved. Site by CMS4i.